• <tr id="66666"></tr>
    <tr id="66666"><code id="66666"></code></tr>
  • <tr id="66666"><input id="66666"></input></tr>
  • <legend id="66666"><code id="66666"></code></legend>
    <center id="66666"></center>
  • 产品展示
    PRODUCT DISPLAY

    打印当前页

    免费咨询:021-67610176

    发邮件给我们:market@hsiyen.cn

    分享到:
    产品展示您现在的位置: 首页 > 产品展示 > > 美国戴安Dionex > 077972美国戴安Dionex Acclaim Carbonyl LC Column 液相色谱柱

    美国戴安Dionex Acclaim Carbonyl LC Column 液相色谱柱

    简要描述:

    戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其*达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
    戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

    型号 077972
    厂商性质 代理商
    更新日期 2017-10-31

    美国戴安Dionex Acclaim Carbonyl LC Column 液相色谱柱

    Acclaim Carbonyl LC Column 

    High Resolution HPLC of Aldehyde and Ketone Contaminants

    The Thermo Scientific Acclaim* Carbonyl C18 HPLC columns are designed specifically for superior resolution and high-throughput separation for DNPH derivatives of aldehydes and ketones regulated by the U.S. Environmental Protection Agency (EPA) in methods such as EPA 554, EPA 8315, EPA 1667, EPA TO-11, and by the California Environmental Protection Agency Air Resources Board in method CARB 1004.

    • High efficiency for UHPLC performance
    • Rugged columns with good lot-to-lot reproducibility
    • Proven robust methods

    Carbonyl compounds, including low molecular weight aldehydes and ketones, cause environmental and health concerns. Because of their highly volatile and reactive nature, carbonyl compounds are often converted to the dinitrophenylhydrazine (DNPH) derivatives prior to analysis. The Acclaim Carbonyl C18 columns are high-performance reversed-phase columns specifically designed for high throughput and baseline separation of thirteen DNPH derivatives of aldehydes and ketones regulated by CARB Method 1004. In addition, the same chromatographic method can be applied directly to other regulatory methods such as EPA 554, EPA 8315, and EPA TO-11.

    The columns are available in three particle sizes:  2.2, 3 and 5?m. Smaller particle sizes provide high peak efficiency for fast analysis. Small internal diameter (i.d.) columns (e.g., 2.1 and 3.0 mm) consume less solvents and produce less chemical waste. For high-throughput application, the 2.1 × 100 mm column format combined with high linear velocity should be considered. When high resolution power is desired, a longer column (2.1 × 150 mm) can be used at an optimal linear velocity to achieve even better resolution.

    技术参数:

    Acclaim Carbonyl C18 Column Specifications
    Column chemistryProprietary alkyl group
    Operating pressure limit (recommended)

    800 bar for 2.1 x 150mm; 2.2?m

    600 bar for 2.1 x 150mm; 3.0 ?m

    600 bar for 2.1 x 100mm

    700 bar for 3.0 x 100mm

    600 bar for 3.0 x 150mm

    800 bar for 3.0 x 250mm

    Operating pH range (recommended)2.5–7.5
    Operating flow rate range (recommended)0.4–1.4  mL/min for 3.0 mm i.d. formats
    0.25–0.75  mL/min for 2.1 mm i.d. formats
    Operating temperature (recommended)25 -35 °C

    订购信息:

    Analytical Columns
    Acclaim Carbonyl RSLC Analytical,2.2?m (2.1 x 100mm)077972
    Acclaim Carbonyl RSLC Analytical,2.2?m (2.1 x 150mm)077973
    Acclaim Carbonyl RSLC Analytical,2.2?m (3.0 x 100mm)077974
    Acclaim Carbonyl C18 Column 3?m Analytical (2.1 x 150 mm)079011
    Acclaim Carbonyl C18 Column 3?m Analytical (3.0 x 150 mm)079010
    Acclaim Carbonyl C18 Column 3?m Analytical (3.0 x 250 mm079009
    Acclaim Carbonyl C18 Column 5?m Analytical (4.6 x 150 mm)079008

    Guard Columns
    Acclaim Carbonyl C18 Column 5?m Guard (2.1 x 10 mm), 2/pk079012
    Acclaim Carbonyl C18 Column 5?m Guard (3.0 x 10 mm) , 2/pk079013
    Acclaim Carbonyl C18 Column 5?m Guard (4.6 x 10 mm), 2/pk079014

    留言框

    • 产品:

    • 您的单位:

    • 您的姓名:

    • 联系电话:

    • 常用邮箱:

    • 省份:

    • 详细地址:

    • 补充说明:

    • 验证码:

      请输入计算结果(填写阿拉伯数字),如:三加四=7